Emanuele Zanda
Google reviewRead on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Cable blowing machines · Made in Italy
From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fiber optic cable installation.
Opera, image 1 of 3
Expert advice direct from the manufacturer / Free demonstration on request
Some of our customers.






Keep your installation moving with Fibernet cable blowing machines.
Photos and stories from installers, published by Fibernet.






Read on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Read on Google“I had the chance to try the Opera cable blowing machine on site…”
Read on Google“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”
Stories from installers
Hear the results from the installers themselves. Watch their testimonials right here.
Product videos
Three machines. Find your fit.
Start with the job at hand. Our technician can answer your questions about the right setup.

Compact and lightweight
A compact, lightweight machine for short runs.

Pneumatic power
A pneumatic machine for long cable runs.

Electric, with two gears
For short and long runs. Two gears let you match force and speed to the job.
Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.
Direct from the manufacturer
When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.
Speak to a technicianA specialist technician can help when you need it.
Spare parts ready to ship, direct from the manufacturer.
If your machine breaks down, a replacement may be available within 48 hours.
Check availability and terms with your technician.Get help making the most of your machine, from your very first job.
See it in action before you choose
Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.
Request a free demonstration
Choosing a drill powered cable jetting machine starts with the installation conditions, not an advertised distance or a headline speed. Contractors working on cable blowing projects in Italy need equipment that suits the cable, the duct, the available compressed air, and the practical limits of the worksite. Fibernet brings an Italian manufacturing background to this discussion, supported by a business founded in 2001 and technical experience extending back to the earliest fiber installations in Italy. Its first cable blowing machine, Lady, was introduced in 2021. For buyers comparing equipment, that background provides a useful starting point for a detailed conversation about the actual task: feeding a particular cable through a prepared duct without exceeding the limits specified by the cable and equipment manufacturers. Before requesting a recommendation, record the cable outside diameter, duct internal diameter, duct material, intended section length, and known bends or elevation changes. These details help establish whether a proposed configuration is appropriate and which accessories require confirmation. A drill powered fiber optic cable jetting machine uses mechanical feeding together with compressed airflow; the drill supplies the drive input rather than replacing the air supply. This distinction matters when planning equipment transport and site readiness. A portable drive arrangement does not remove the need to assess compressor pressure, delivered airflow, air quality, and compatible connections. Ask Fibernet which drill characteristics are required for the proposed setup, including permissible speed, torque settings, attachment method, and any operating restrictions. Compatibility should be confirmed rather than assumed from the appearance of the drive connection. The same applies to cable guides, duct adapters, seals, and feeding components: their fit influences both handling and air leakage. On site, preparation is just as important as the machine selection. Inspect the duct route, check that joints are suitable for the intended operation, and verify that the cable can pay off smoothly from its reel. Position the equipment so the cable enters in alignment, without an unnecessarily tight bend immediately before the feed mechanism. Establish clear communication between the feeding position and the receiving point before starting. When assessing a cable jetting machine for fiber optic cable installation, ask how the operator should recognize abnormal resistance and stop safely. Increased drive force is not a substitute for identifying an obstruction, a damaged duct, or unsuitable route geometry. The aim is a controlled installation process with equipment selected around real operating conditions. Contact Fibernet with your project data to discuss an Italian-made solution and clarify the support available in Italy, the United States, and other international locations.
A productive cable blowing operation depends on repeatable preparation and attentive control throughout the run. Begin with a site briefing that defines who controls the drive, who monitors cable payoff, and who confirms progress at the receiving end. Keep these responsibilities clear even on short sections, because an unexpected restriction can develop before the operator sees an obvious problem at the feed point. Review the operating instructions for the selected machine and establish the correct shutdown sequence before introducing compressed air. Connections, seals, protective equipment, and access around the work area should all be checked against the relevant instructions and site requirements. Never loosen a pressurized connection to investigate a fault. For a drill powered cable jetting machine, drive setup deserves particular attention. The drill must match the requirements of the machine configuration, and its controls must allow the operator to maintain the specified operating conditions. Ask Fibernet to explain the appropriate settings and any limitations for the equipment under consideration. Do not assume that a higher drill rating automatically improves installation performance. Excessive mechanical input can create problems when the cable is no longer advancing freely. Feeding components should be adjusted according to the manufacturer's procedure, with enough engagement to move the cable correctly without applying inappropriate pressure to its jacket. Cable construction, jacket material, and diameter can affect the suitable setup, so settings should not simply be copied from a previous job involving a different cable. Teams evaluating a drill driven cable jetting machine should also consider how they will manage the reel. A reel that turns unevenly or introduces excessive resistance can disrupt an otherwise well-prepared operation. Arrange stable support, suitable alignment, and sufficient working space so the cable reaches the machine without crossing sharp edges or being dragged over unsuitable surfaces. Confirm whether lubrication is recommended for the specific cable and duct combination, and use only a compatible product when required. Compressed air preparation is another operational priority. Available pressure alone does not describe the full capability of the air supply; delivered flow and the conditions at the machine also matter. Have the relevant compressor information ready when discussing a drill powered cable blowing machine with Fibernet. During installation, observe cable movement and follow the monitoring methods provided for the selected equipment. If progress slows unexpectedly, stop and investigate rather than repeatedly increasing the drive input. Record the conditions of successful runs, including cable and duct dimensions, route characteristics, and the approved setup. These records can support more informed planning for comparable sections, while recognizing that previous results do not guarantee the same distance or speed on a different route.
Buying cable blowing equipment is also a decision about maintenance, configuration management, and access to useful technical information after delivery. Fibernet is a family-led Italian business whose development reflects the technical background of founder Giancarlo Trinei and the subsequent involvement of Matteo, Marta, and Ismael. For a contractor, the practical value of that history lies in discussing the equipment directly with a company focused on how its products are used. A purchasing conversation should move beyond the basic machine description and establish what is included, what must be supplied separately, and what support arrangements apply to the destination where the equipment will operate. For projects in Italy, request a quotation that clearly identifies the proposed configuration and any accessories needed for your cable and duct sizes. If your company also manages work in the United States or elsewhere, discuss Fibernet's support in the United States and worldwide, including contact procedures, parts availability, shipping arrangements, and the handling of technical questions. Confirm these details for your location rather than assuming identical service terms in every market. When considering a drill powered cable jetting machine, ask for the documentation required to assess safe operation, compatibility, routine inspection, and maintenance. Clarify which components are subject to wear and how operators should identify when replacement is necessary. Feeding surfaces, guides, and seals perform different functions, and their inspection should follow the specific product instructions. Keeping appropriate replacement items available may help avoid interruptions, but the recommended stock should reflect actual usage and the selected configuration rather than a generic shopping list. Contractors comparing a battery powered cable jetting machine with a drill-driven arrangement should ask exactly what the battery powers. In a cordless drill configuration, battery energy supplies the mechanical drive; compressed air requirements still need separate verification. Battery runtime, spare battery planning, and charging access therefore form only one part of the operating plan. Avoid treating portable drive power as evidence that the complete installation system is independent of external resources. A useful quotation request describes the jobs you expect to perform, not just the product name you have searched for. Include anticipated cable sizes, duct dimensions, typical section lengths, route constraints, compressor details, and how frequently the equipment will move between sites. Explain whether one crew will use the machine regularly or several teams will share it, because documentation, accessory organization, and maintenance responsibilities become especially important with shared equipment. Fibernet can then discuss its Italian-made cable blowing equipment against a clearer set of requirements. The objective is an informed purchase with realistic expectations about setup, application limits, consumables, and ongoing assistance, rather than a promise of universal performance across every installation.
Fill out the form and discover what Fibernet Srl can do for you!
Contact us!Before you get started
If you prefer, speak to us directly.
+39 346 652 9915Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.
Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.
To get a price, contact a Fibernet advisor using the form or call +39 346 652 9915.
Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.
Tell us about your job. We’ll help you find the right cable blowing machine.