Cable blowing machines · Made in Italy

Looking for "drill driven cable blower"?

From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fiber optic cable installation.

Expert advice direct from the manufacturer / Free demonstration on request

Some of our customers.

Keep your installation moving with Fibernet cable blowing machines.

On-site training
US & Worldwide Technical support
Spare parts ready to ship
Replacement machine if yours breaks down

Photos and stories from installers, published by Fibernet.

Cable blowing machines in action.

Three installers testing the Opera cable blowing machine on siteEnlarge +
Opera with the installers on site.
A Fibernet technician showing installers how to use the cable blowing machineEnlarge +
Hands-on demonstration with a Fibernet technician.
Close-up of a Geniale cable blowing machine during an outdoor testEnlarge +
A closer look at Geniale in the field.
GoogleExcellentBased on 176 reviewsRead the reviews

Emanuele Zanda

Google review
Google

“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”

Read on Google

Giuseppe Ares Rosa

Google review
Google

“I had the chance to try the Opera cable blowing machine on site…”

Read on Google

Paolo Manna

Google review
Google

“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”

Read on Google

Stories from installers

See the difference on site.

Testimonial · Opera

“We cut our working time by 80%.”

Experience on site

“2 km of cable in half a day.”

Hear the results from the installers themselves. Watch their testimonials right here.

Product videos

Meet the machines.

Product overview

LADY

Product overview

GENIALE

Product overview

OPERA

Three machines. Find your fit.

Every installation is different.
Find your cable blowing machine.

Start with the job at hand. Our technician can answer your questions about the right setup.

01 / SHORT RUNSFibernet Lady cable blowing machine

Compact and lightweight

LADY

A compact, lightweight machine for short runs.

Cable diameter
1.2–10 mm
Duct diameter
5–16 mm
Pushing force
Up to 150 N
Maximum speed
80 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Lady
02 / LONG RUNSFibernet Opera pneumatic cable blowing machine

Pneumatic power

OPERA

A pneumatic machine for long cable runs.

Cable diameter
4–16 mm
Duct diameter
7–63 mm
Pushing force
Up to 900 N
Maximum speed
110 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Opera
03 / ELECTRIC DRIVEFibernet Geniale electric cable blowing machine

Electric, with two gears

GENIALE

For short and long runs. Two gears let you match force and speed to the job.

Cable diameter
1.2–8 mm
Duct diameter
5–16 mm
Pushing force
400 / 110 NGear 1 / Gear 2
Maximum speed
60 / 125 m/minGear 1 / Gear 2
Cable protection
Twin drive beltsrubber-coated
I’m interested in Geniale

Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.

Direct from the manufacturer

The machine matters.
Who supports you
matters even more.

When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.

Speak to a technician

Direct support

A specialist technician can help when you need it.

Spare parts available

Spare parts ready to ship, direct from the manufacturer.

Replacement machine

If your machine breaks down, a replacement may be available within 48 hours.

Check availability and terms with your technician.

Dedicated training

Get help making the most of your machine, from your very first job.

See it in action before you choose

Put it to the test.
On your own site.

Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.

Request a free demonstration
An operator using an Opera cable blowing machine on site

Match your cable blowing equipment to the installation

Choosing a drill driven cable blower starts with the installation conditions, not simply the length of cable on the reel. Contractors need to understand the relationship between cable diameter, duct internal diameter, route geometry, compressed air supply, and the force the cable can safely withstand. These factors determine whether a proposed configuration is suitable and what preparation is necessary before work begins. Fibernet gives installation businesses a point of contact for discussing cable blowing equipment with an Italian manufacturer whose technical background informs its approach to product development. For American contractors evaluating equipment made in Italy, that conversation should begin with actual job specifications rather than assumptions about universal compatibility or guaranteed installation distances. A drill driven fiber cable blower combines mechanically assisted cable feeding with compressed air introduced into the duct. The drill provides the drive input, while airflow helps transport the cable along the route. However, the drill does not replace the compressor, and additional drill torque is not a substitute for correct setup. The complete operating arrangement must match the machine instructions, cable limits, and duct characteristics. Before selecting equipment, provide the cable outside diameter, its published installation limits, the duct dimensions, and an outline of the planned route. Include the number and severity of bends, elevation changes, access points, and any available information about duct continuity. Compressor pressure and delivered airflow also need to be assessed against the requirements of the proposed machine configuration. A compressor specification alone does not establish the performance available at the equipment inlet because hoses, connections, and other restrictions can affect delivery. When discussing a cable blower for fiber optic cable installation, ask which cable guides, seals, and duct connections are required for your specific combination. Incorrect sizing can compromise sealing, cable guidance, or feeding consistency. Confirm the compatible drill characteristics and any operating restrictions before treating an existing cordless drill as a suitable power source. Request the relevant documentation instead of assuming that all drills, cables, and ducts can be interchanged. A practical purchasing decision should also consider setup access, handling between work locations, and the availability of the components needed for future cable sizes. Equipment suitability includes what happens before and after the blowing run, not just movement through the duct. Share representative project conditions with Fibernet to establish which product information and configuration details you need. This approach helps procurement staff and field supervisors evaluate the same requirements, reduces avoidable misunderstandings, and creates a clearer basis for requesting a quotation. The objective is a properly matched installation setup with documented operating limits, rather than a purchase based on a headline distance or an unsupported productivity promise.

Prepare the duct route and manage the blowing run

Reliable cable blowing depends on preparation that the installation crew can verify at the worksite. Before positioning a drill driven cable blower, review the route records and confirm that the intended duct section is ready for cable installation. Check continuity, inspect accessible connections, and follow the approved procedures for assessing duct condition. Water, debris, damaged sections, or unsuitable joints can interfere with airflow and cable movement. Discovering these problems before the cable enters the duct is generally easier to manage than investigating an obstruction during a partially completed run. Establish a stable working position for the machine and arrange the cable reel so that the cable pays off smoothly without dragging across sharp edges or developing uncontrolled loops. The entry path should respect the cable manufacturer's minimum bend radius. Crew members should also have enough room to observe the cable as it approaches the feeding mechanism. Good positioning supports controlled handling and makes changes in cable behavior easier to identify. When preparing a drill driven cable blowing machine, follow the manufacturer's instructions for installing guides, seals, and duct adapters. Check that the selected components correspond to the actual cable and duct dimensions rather than relying on nominal descriptions alone. Inspect contact surfaces and replace worn components where required. If lubricant is appropriate, use only a product and application method approved for the cable, duct, and equipment involved. Lubrication should not be used to disguise a damaged route or an unsuitable configuration. Compressed air requires its own safety checks. Confirm that hoses, fittings, and connections are suitable for the intended operating conditions, and follow the specified connection and depressurization procedures. Keep personnel clear of unsecured duct ends and other potential discharge points. Never loosen a pressurized connection to investigate a problem. A clear communication method between the feed position and the receiving location helps the team coordinate starting, stopping, and confirming cable arrival. During operation, monitor progress rather than assuming that continuous drill movement means the installation is proceeding correctly. Unexpected resistance, slipping, abnormal cable behavior, or a sudden change in advancement should prompt a controlled stop and investigation. Increasing the driving force without understanding the cause can expose the cable to damage. A drill driven fiber optic cable blower should be operated within its documented limits and the cable manufacturer's installation requirements throughout the run. Keep a basic job record that includes the cable and duct specifications, route section, equipment configuration, relevant operating observations, and any interruption. These records can help distinguish equipment setup issues from route problems when planning similar work. They also provide useful information when requesting technical assistance. Fibernet can be approached with these concrete details when discussing equipment suitability or support needs, allowing the conversation to focus on the conditions encountered rather than an incomplete description of the result.

Italian manufacturing with support for American installation teams

For an installation business, the equipment purchase is only one part of the decision. Access to clear product information, appropriate replacement components, and technical assistance also matters when crews depend on cable blowing equipment across successive projects. Fibernet combines its Italian manufacturing identity with assistance in the United States and worldwide, giving American businesses a contact point for discussing equipment made in Italy. Before ordering, buyers should confirm the support arrangements applicable to their location, including contact channels, component availability, shipping procedures, and any warranty conditions associated with the proposed product. The company's background provides context for its focus on practical installation equipment. Founded in 2001, Fibernet draws on the technical experience of Giancarlo Trinei, whose work with early installations in Italy began in the 1980s. The business later welcomed Matteo, Marta, and Ismael into its development, maintaining its family foundations while pursuing international growth. In 2021, Fibernet launched its first cable blowing machine, Lady. This history explains the company's involvement in the sector, but equipment selection should still be based on the documented specifications of the particular model under consideration. When evaluating a drill driven cable blower, ask Fibernet to identify the suitable configuration for your installation requirements and to explain the relevant operating documentation. A useful inquiry includes the cable sizes your crews regularly handle, duct dimensions, typical route conditions, and the compressor resources available. If your business works across multiple project types, explain the differences between them. This helps establish whether one configuration addresses the intended work or whether different accessories or equipment arrangements need consideration. For a drill driven cable jetting machine, procurement questions should extend beyond the initial purchase price. Ask which components are supplied, which are optional, and which may require periodic inspection or replacement. Clarify how to identify and order the correct seals, guides, and connections. Confirm the drill requirements and determine whether the drill and compressor are included or must be sourced separately. These details support a more accurate comparison of complete working setups and help prevent missing components from becoming a problem when equipment reaches the site. American contractors considering a drill driven fiber blower should also discuss how technical questions will be handled after delivery. Useful support requests include the equipment identification, photographs of the setup where appropriate, cable and duct measurements, and a concise description of the operating conditions. Providing specific information makes troubleshooting more focused without assuming that every difficulty originates in the machine. Explore Fibernet's website to discuss your proposed applications, request available product documentation, and obtain a quotation based on the configuration you actually need. Italian manufacturing and international assistance are most valuable when combined with a clear understanding of equipment compatibility, operating responsibilities, and the practical requirements of the crew using it.

Still looking for information about drill driven cable blower?

Fill out the form and discover what Fibernet Srl can do for you!

Contact us!

Before you get started

Have a question?
Start here.

If you prefer, speak to us directly.

+39 346 652 9915
Which cable blowing machine is right for my site?

Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.

Can I see the machine in action before I buy it?

Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.

How much does a Fibernet cable blowing machine cost?

To get a price, contact a Fibernet advisor using the form or call +39 346 652 9915.

What support will I get after purchase?

Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.

Your next project
starts with the right choice.

Tell us about your job. We’ll help you find the right cable blowing machine.

CallRequest information